{"id":309,"date":"2024-12-06T09:12:14","date_gmt":"2024-12-06T08:12:14","guid":{"rendered":"https:\/\/blog.boruc.pl\/?p=309"},"modified":"2025-03-05T08:50:12","modified_gmt":"2025-03-05T07:50:12","slug":"woda-na-dachu","status":"publish","type":"post","link":"https:\/\/blog.boruc.pl\/index.php\/2024\/12\/06\/woda-na-dachu\/","title":{"rendered":"Woda na dachu"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>wymiarowanie kanalizacji deszczowej z dachu<br>PN EN 12053-3<br><br><strong>DIN 1986<\/strong><br>R\u00f3\u017cnice w wymiarowaniu przelew\u00f3w awaryjnych z dach\u00f3w wed\u0142ug norm EN 12056-3, DIN 12056 i DIN 1986 dotycz\u0105 kilku kluczowych aspekt\u00f3w:<\/p>\n\n\n\n<p><strong>DIN 1986<\/strong>: Uwzgl\u0119dnia obci\u0105\u017cenia wod\u0105, w tym efekt tzw. leja zlewowego, co jest istotne przy projektowaniu dach\u00f3w o konstrukcji lekkiej<a>2<\/a>.<\/p>\n\n\n\n<p><strong>Algorytmy obliczeniowe<\/strong>:<\/p>\n\n\n\n<p><strong>EN 12056-3<\/strong>: Norma ta zaleca stosowanie przelew\u00f3w awaryjnych, ale nie precyzuje szczeg\u00f3\u0142owych algorytm\u00f3w obliczeniowych<a>1<\/a>.<\/p>\n\n\n\n<p><strong>DIN 1986<\/strong>: W Niemczech, mimo obowi\u0105zywania EN 12056-3, wprowadzono krajowe przepisy (np. KOSTRA-Karte), kt\u00f3re dok\u0142adnie okre\u015blaj\u0105 algorytmy oblicze\u0144 dla odwodnienia g\u0142\u00f3wnego i awaryjnego<a>1<\/a>.<\/p>\n\n\n\n<p><strong>Przepustowo\u015b\u0107 przelew\u00f3w<\/strong>:<\/p>\n\n\n\n<p><strong>EN 12056-3<\/strong>: Nie podaje szczeg\u00f3\u0142owych wymaga\u0144 dotycz\u0105cych przepustowo\u015bci przelew\u00f3w<a>1<\/a>.<\/p>\n\n\n\n<p><strong>DIN 1986<\/strong>: Wymaga, aby przelewy awaryjne mia\u0142y odpowiedni\u0105 przepustowo\u015b\u0107, kt\u00f3ra jest dok\u0142adnie okre\u015blona w przepisach krajowych<a>1<\/a>.<\/p>\n\n\n\n<p><strong>Rodzaje przelew\u00f3w<\/strong>:<\/p>\n\n\n\n<p><strong>EN 12056-3<\/strong>: Zaleca stosowanie przelew\u00f3w przez attyk\u0119 oraz wpust\u00f3w dachowych<a>1<\/a>.<\/p>\n\n\n\n<p><strong>DIN 1986<\/strong>: Preferuje stosowanie wpust\u00f3w dachowych, kt\u00f3re maj\u0105 wy\u017csz\u0105 przepustowo\u015b\u0107 w por\u00f3wnaniu do przelew\u00f3w przez attyk\u0119<a>1<\/a>.<\/p>\n\n\n\n<p><strong>Obci\u0105\u017cenia wod\u0105<\/strong>:<\/p>\n\n\n\n<p><strong>EN 12056-3<\/strong>: Nie okre\u015bla szczeg\u00f3\u0142owo, jak oblicza\u0107 obci\u0105\u017cenia wod\u0105 na dachach<a>1<\/a>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-8-1024x576.png\" alt=\"\" class=\"wp-image-310\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-8-1024x576.png 1024w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-8-300x169.png 300w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-8-768x432.png 768w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-8.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/inzynierbudownictwa.pl\/odwodnianie-glowne-i-awaryjne-dachow-plaskich-obciazenia-polaci-slupem-wody-dobor-systemu-odwodniania\/\"><img loading=\"lazy\" decoding=\"async\" width=\"780\" height=\"943\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-14.png\" alt=\"\" class=\"wp-image-318\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-14.png 780w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-14-248x300.png 248w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-14-768x928.png 768w\" sizes=\"auto, (max-width: 780px) 100vw, 780px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><a href=\"https:\/\/pekabex.com\/wp-content\/uploads\/2024\/08\/PEKABEX-Analiza-bezpieczenstwa-dachow-wielkopowierzchniowych-PL-WEB.pdf\" data-type=\"link\" data-id=\"https:\/\/pekabex.com\/wp-content\/uploads\/2024\/08\/PEKABEX-Analiza-bezpieczenstwa-dachow-wielkopowierzchniowych-PL-WEB.pdf\">cyt<\/a><br>&#8230; wyznaczeniem ilo\u015bci wody, jaka jest w stanie nagromadzi\u0107 si\u0119 na dachu wielkopowierzchniowej hali w trakcie trwania intensywnych opad\u00f3w. Metodyk\u0119 obliczenia nat\u0119\u017cenia deszczu przyjmuje projektant instalacji<br>w uzgodnieniu z inwestorem lub gestorem sieci deszczowej. Wi\u0119kszo\u015b\u0107 projektant\u00f3w instalacji korzysta w tym celu z metody B\u0142aszczyka [<a href=\"https:\/\/poradnikprojektanta.pl\/jak-wyznaczyc-miarodajne-natezenie-deszczu-dane-opadowe-w-polsce\/\" data-type=\"link\" data-id=\"https:\/\/poradnikprojektanta.pl\/jak-wyznaczyc-miarodajne-natezenie-deszczu-dane-opadowe-w-polsce\/\">S4<\/a>]. Standardem jest przyjmowanie nat\u0119\u017cenia deszczu, obliczonego wg r\u00f3wnania B\u0142aszczyka [Kotowski A., Ka\u017amierczak B., Dancewicz A., Modelowanie opad\u00f3w do wymiarowania kanalizacji, Polska Akademia Nauk, Komitet In\u017cynierii<br>L\u0105dowej i Wodnej, Instytut Podstawowych Problem\u00f3w Techniki, Warszawa 2010.], dla 15-minutowego deszczu obliczeniowego o cz\u0119stotliwo\u015bci powtarzania si\u0119 raz na pi\u0119\u0107 lat c = 5, tj. dla prawdopodobie\u0144stwa p = 20% jako warto\u015b\u0107 q = 131,4 dm\u00b3\/s\u00b7ha (miarodajne nat\u0119\u017cenie deszczu). Przy za\u0142o\u017ceniu kompletnie niedro\u017cnego systemu odwadniaj\u0105cego, po 15 minutach opad\u00f3w deszczu o takiej intensywno\u015bci na jednym metrze kwadratowym dachu zbierze si\u0119 11,8 mm s\u0142upa wody, co odpowiada ci\u0119\u017carowi r\u00f3wnemu 11,8 kg\/m\u00b2 Dalsze stosowanie modelu B\u0142aszczyka, jako standardu, wp\u0142ywa na zmniejszenie bezpiecze\u0144stwa projektowanych i modernizowanych system\u00f3w odwodnienia w Polsce [Licznar P., Zaleski J., redaktorzy. Metodyka opracowania Polskiego Atlasu Nat\u0119\u017cenia Deszcz\u00f3w (PANDa). Instytut Meteorologii i Gospodarki Wodnej \u2013 \u2013 Pa\u0144stwowy Instytut Badawczy; 2020. (Licznar P., Zaleski J.,Seria publikacji naukowo-badawczych IMGW-PIB).], co przek\u0142ada si\u0119 tak\u017ce na bezpiecze\u0144stwo u\u017cytkowania hal wielkopowierzchniowych. Nieaktualno\u015b\u0107 modelu B\u0142aszczyka wynika przede wszystkim ze zmian rozk\u0142ad\u00f3w w czasie i przestrzeni ilo\u015bci opad\u00f3w, kt\u00f3rych g\u0142\u00f3wnym czynnikiem s\u0105 silne zmiany klimatyczne [9]. W Niemczech znaczenie tego zagadnienia zosta\u0142o zauwa\u017cone trzydzie\u015bci lat temu, a jego rozwi\u0105zaniem jest aktualizowany systematycznie og\u00f3lnokrajowy atlas opadowy KOSTRA (niem. KOordinierte STarkniederschlags-Regionalisierungs-Auswertungen). W Polsce standard ten zosta\u0142 osi\u0105gni\u0119ty w ramach opracowania Polskiego Atlasu Nat\u0119\u017ce\u0144 Deszcz\u00f3w (PANDa), zapewnia on cyfrow\u0105 platform\u0119 zawieraj\u0105c\u0105 informacje o nat\u0119\u017ceniach deszcz\u00f3w miarodajnych dla wszystkich miast w Polsce. Traktuj\u0105c jak poprzednio, jako punkt odniesienia 15-minutowy opad deszczu o prawdopodobie\u0144stwie wyst\u0105pienia p = 20% (c = 5 lat), miarodajne nat\u0119\u017cenie deszczu q b\u0119dzie r\u00f3wne 169,89 dm\u00b3\/s\u00b7ha (rys. 2). Przy za\u0142o\u017ceniu kompletnie niedro\u017cnego systemu odwadniaj\u0105cego, po 15 minutach opad\u00f3w deszczu o takiej intensywno\u015bci na jednym metrze kwadratowym dachu zbierze si\u0119 15,3 mm s\u0142upa wody, co odpowiada ci\u0119\u017carowi 15,3 kg\/m\u00b2.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"414\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-9.png\" alt=\"\" class=\"wp-image-311\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-9.png 853w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-9-300x146.png 300w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-9-768x373.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n\n\n\n<p>Przedstawione powy\u017cej dane liczbowe wyra\u017anie wskazuj\u0105, \u017ce takie dodatkowe obci\u0105\u017cenie stanowi\u0142oby ponad 4-krotne przekroczenie zapasu obliczeniowego, omawianego w niniejszym punkcie opinii dla kratownicy stalowej, oraz ok. 60% wybranie zapasu w przypadku d\u017awigara strunobetonowego. <br>Stosuj\u0105c <a href=\"https:\/\/atlaspanda.pl\">model PANDa<\/a> do wyznaczenia czasu trwania intensywnych opad\u00f3w jakie, przy ca\u0142kowicie niedro\u017cnej instalacji odwodnieniowej, spowodowa\u0142oby wybranie omawianego pe\u0142nego zapasu kratownicy stalowej (3,7 kg\/m\u00b2) otrzymano warto\u015b\u0107 poni\u017cej 5 minut. Post\u0119puj\u0105c analogicznie w przypadku d\u017awigara strunobetonowego, pe\u0142ne wybranie omawianego zapasu (24,3 kg\/m\u00b2) uzyskano by po up\u0142ywie ponad 60 minut.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.aco.pl\/fileadmin\/standard\/aco-pl\/pedefy\/katalogi\/Katalog_SWM_ACO_SPIN_wpusty_dachowe_i_parkingowe.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"451\" height=\"630\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-10.png\" alt=\"\" class=\"wp-image-312\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-10.png 451w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-10-215x300.png 215w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.aco.pl\/fileadmin\/standard\/aco-pl\/pedefy\/katalogi\/Katalog_SWM_ACO_SPIN_wpusty_dachowe_i_parkingowe.pdf\"><img loading=\"lazy\" decoding=\"async\" width=\"779\" height=\"431\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-11.png\" alt=\"\" class=\"wp-image-313\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-11.png 779w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-11-300x166.png 300w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-11-768x425.png 768w\" sizes=\"auto, (max-width: 779px) 100vw, 779px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.nedzink.com\/pl\/obliczenia-odwodnienia-dachu\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"595\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-12-1024x595.png\" alt=\"\" class=\"wp-image-314\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-12-1024x595.png 1024w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-12-300x174.png 300w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-12-768x446.png 768w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-12.png 1041w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"396\" height=\"836\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-13.png\" alt=\"\" class=\"wp-image-315\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-13.png 396w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-13-142x300.png 142w\" sizes=\"auto, (max-width: 396px) 100vw, 396px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><a href=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7302093329368834050-eLg0?utm_source=share&amp;utm_medium=member_desktop&amp;rcm=ACoAAAMsOE8B_kBRYR8s8cY7G5yy_Vc-9TR1EuM\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7302093329368834050-eLg0?utm_source=share&amp;utm_medium=member_desktop&amp;rcm=ACoAAAMsOE8B_kBRYR8s8cY7G5yy_Vc-9TR1EuM\">Zamodelowana zosta\u0142a jedna zlewnia dachu wielkopowierzchniowego o parametrach przedstawionych we wcze\u015bniejszych postach.<\/a><br><br>W SWMM za\u0142o\u017cono geometri\u0119 w ko\u0144cowej fazie ugi\u0119cia konstrukcji jako 75% ugi\u0119cia z wcze\u015bniejszych modeli \u2013 dodali\u015bmy troch\u0119 sztywno\u015bci, aby wyniki by\u0142y jak najbardziej zbli\u017cone do warunk\u00f3w w istniej\u0105cych halach wielkopowierzchniowych z d\u017awigarem stalowym 24 m.<br>Deszcz trwa tylko 5 minut, ale poziom wody nadal ro\u015bnie przez pewien czas po jego zako\u0144czeniu.<br>Na filmie r\u00f3wnolegle do wynik\u00f3w z SWMM przedstawiono map\u0119 g\u0142\u0119boko\u015bci wody oraz schemat ugi\u0119\u0107 wykonany w programie RFEM.<br><br>&#x1f4cc; Wnioski:<br>&#x2714; Przelew awaryjny o szeroko\u015bci 2 m praktycznie nie dzia\u0142a.<br>&#x2714; Maksymalna g\u0142\u0119boko\u015b\u0107 wody to 175 mm (przy zadanej sztywno\u015bci, kt\u00f3ra jest o 50% wi\u0119ksza od wystarczaj\u0105cej do spe\u0142nienia warunk\u00f3w normowych).<br>&#x2714; Odwodnienie podstawowe o przepustowo\u015bci 300 l\/s, roz\u0142o\u017cone r\u00f3wnomiernie \u2013 wpust na prz\u0119\u015ble 24 m odprowadza wod\u0119 z maksymaln\u0105 wydajno\u015bci\u0105 przez 25 minut po zako\u0144czeniu opadu.<br>&#x2714; Pozosta\u0142e wpusty dzia\u0142aj\u0105 nieefektywnie.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"566\" height=\"294\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074209169.png\" alt=\"\" class=\"wp-image-338\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074209169.png 566w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074209169-300x156.png 300w\" sizes=\"auto, (max-width: 566px) 100vw, 566px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"426\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074238834.png\" alt=\"\" class=\"wp-image-339\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074238834.png 665w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074238834-300x192.png 300w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"385\" height=\"207\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074308674.png\" alt=\"\" class=\"wp-image-340\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074308674.png 385w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image_2025-03-03_074308674-300x161.png 300w\" sizes=\"auto, (max-width: 385px) 100vw, 385px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"1024\" src=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-15-853x1024.png\" alt=\"\" class=\"wp-image-320\" srcset=\"https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-15-853x1024.png 853w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-15-250x300.png 250w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-15-768x922.png 768w, https:\/\/blog.boruc.pl\/wp-content\/uploads\/2024\/12\/image-15.png 945w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>cykl wpis\u00f3w na linkedIn (autor <a href=\"https:\/\/www.linkedin.com\/in\/krzysztof-kozie%C5%82-020364164?miniProfileUrn=urn%3Ali%3Afsd_profile%3AACoAACc1JRgBo6DqKhXNX4OFPgErh3Rzjy3YT9w&amp;lipi=urn%3Ali%3Apage%3Ad_flagship3_detail_base%3BqK4%2F5ZJKSwKUeCVsGAJtwg%3D%3D\">Krzysztof Kozie\u0142 \u2022 Projektant w Optimal Design of Structures<\/a> ) &#8211; <a href=\"https:\/\/www.linkedin.com\/pulse\/wp%C5%82yw-skr%C3%B3cenia-pas%C3%B3w-g%C3%B3rnych-kratownic-na-\/?trackingId=wtLr%2FxO4Xm7cssiG2%2FExxw%3D%3D\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/pulse\/wp%C5%82yw-skr%C3%B3cenia-pas%C3%B3w-g%C3%B3rnych-kratownic-na-\/?trackingId=wtLr%2FxO4Xm7cssiG2%2FExxw%3D%3D\">artyku\u0142 IN<\/a><br>1. <a href=\"https:\/\/www.linkedin.com\/feed\/update\/urn:li:activity:7270208841219219456\/\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/feed\/update\/urn:li:activity:7270208841219219456\/\">link<\/a> <br>2. <a href=\"https:\/\/www.linkedin.com\/feed\/update\/urn:li:activity:7270889930355089408\/\">link<\/a><br>3. <a href=\"https:\/\/www.linkedin.com\/feed\/update\/urn:li:activity:7271664412594196480\/\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/feed\/update\/urn:li:activity:7271664412594196480\/\">link<\/a><br>4. <a href=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7273697748766334976-GBL3?utm_source=share&amp;utm_medium=member_desktop\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7273697748766334976-GBL3?utm_source=share&amp;utm_medium=member_desktop\">link<\/a><br>5. <a href=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_dlubal-rfem-pondingload-activity-7280545159140769793-pCjt?utm_source=share&amp;utm_medium=member_desktop\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_dlubal-rfem-pondingload-activity-7280545159140769793-pCjt?utm_source=share&amp;utm_medium=member_desktop\">link<\/a><br>6. <a href=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7302093329368834050-eLg0?utm_source=share&amp;utm_medium=member_desktop&amp;rcm=ACoAAAMsOE8B_kBRYR8s8cY7G5yy_Vc-9TR1EuM\" data-type=\"link\" data-id=\"https:\/\/www.linkedin.com\/posts\/krzysztof-kozie%C5%82-020364164_konstrukcjestalowe-projektowaniekonstrukcji-activity-7302093329368834050-eLg0?utm_source=share&amp;utm_medium=member_desktop&amp;rcm=ACoAAAMsOE8B_kBRYR8s8cY7G5yy_Vc-9TR1EuM\">link<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>wymiarowanie kanalizacji deszczowej z dachuPN EN 12053-3 DIN 1986R\u00f3\u017cnice w wymiarowaniu przelew\u00f3w awaryjnych z dach\u00f3w wed\u0142ug norm EN 12056-3, DIN 12056 i DIN 1986 dotycz\u0105 kilku kluczowych aspekt\u00f3w: DIN 1986: Uwzgl\u0119dnia obci\u0105\u017cenia wod\u0105, w tym efekt tzw. leja zlewowego, co jest istotne przy projektowaniu dach\u00f3w o konstrukcji lekkiej2. Algorytmy obliczeniowe: EN 12056-3: Norma ta zaleca &#8230; <a title=\"Woda na dachu\" class=\"read-more\" href=\"https:\/\/blog.boruc.pl\/index.php\/2024\/12\/06\/woda-na-dachu\/\" aria-label=\"More on Woda na dachu\">Czytaj dalej<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-309","post","type-post","status-publish","format-standard","hentry","category-woda"],"_links":{"self":[{"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/posts\/309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/comments?post=309"}],"version-history":[{"count":5,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/posts\/309\/revisions"}],"predecessor-version":[{"id":341,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/posts\/309\/revisions\/341"}],"wp:attachment":[{"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/media?parent=309"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/categories?post=309"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.boruc.pl\/index.php\/wp-json\/wp\/v2\/tags?post=309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}